<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Alarmes Archives - FRIAX Industrie</title>
	<atom:link href="https://friax.fr/category/alarmes/feed/" rel="self" type="application/rss+xml" />
	<link>https://friax.fr/category/alarmes/</link>
	<description></description>
	<lastBuildDate>Thu, 18 Apr 2024 17:08:39 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://friax.fr/wp-content/uploads/2021/04/Logo-app-Friax-150x150.png</url>
	<title>Alarmes Archives - FRIAX Industrie</title>
	<link>https://friax.fr/category/alarmes/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Alarme AHRH humidité trop forte</title>
		<link>https://friax.fr/alarme-ahrh-humidite-trop-forte/</link>
		
		<dc:creator><![CDATA[Service client 3]]></dc:creator>
		<pubDate>Thu, 18 Apr 2024 17:08:39 +0000</pubDate>
				<category><![CDATA[Alarmes]]></category>
		<guid isPermaLink="false">https://friax.fr/?p=68956</guid>

					<description><![CDATA[<p>Le code erreur AHRH sur votre télécommande ou sur l&#8217;écran de votre Winespervisor 3 signifie que le taux d&#8217;humidité dans votre cave est trop élevé. L&#8217;humidité moyenne la mieux adaptée à une cave à vin doit être comprise entre 55 et 75 %. Des variations périodiques plus ou moins importantes peuvent intervenir sans affecter les [&#8230;]</p>
<p>This article <a href="https://friax.fr/alarme-ahrh-humidite-trop-forte/">Alarme AHRH humidité trop forte</a> first appeared on <a href="https://friax.fr">FRIAX Industrie</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Le code erreur AHRH sur votre télécommande ou sur l&rsquo;écran de votre Winespervisor 3 signifie que le taux d&rsquo;humidité dans votre cave est trop élevé.</p>
<p>L&rsquo;humidité moyenne la mieux adaptée à une cave à vin doit être comprise entre 55 et 75 %. Des variations périodiques plus ou moins importantes peuvent intervenir sans affecter les bouteilles.<br />
Si l&rsquo;humidité de la cave est systématiquement supérieure à 80%, vérifiez tout d&rsquo;abord le réglage FSTY de la ventilation de l&rsquo;unité intérieure (voir notice de mise en service).<br />
Ce paramètre permet de définir l&rsquo;état du ventilateur lorsque la cave a atteint ses points de température et d&rsquo;humidité.<br />
3 possibilités de réglage :<br />
-GV : réglage usine, le ventilateur reste à sa vitesse nominale de fonctionnement pour assurer une circulation maximale de l&rsquo;air dans la cave. Inconvénient, l&rsquo;eau contenue dans le bac sous l&rsquo;évaporateur continue d&rsquo;humidifier l&rsquo;air circulant dans l&rsquo;appareil, ce qui selon la configuration de la cave peut trop augmenter l&rsquo;humidité.<br />
-PV : Le ventilateur passe en petite vitesse pour les appareils équipés de ventilateurs multi-vitesses (EVA2, H2OA, EVG, EVI, MPCG, MPCA). Dans ce cas, l’air est mélangé avec peu d’impact sur l’humidification.<br />
-OFF : Dès que les points de température et d&rsquo;humidité sont atteints, la ventilation de la cave s&rsquo;arrête. La première valeur demandée redémarrera le système de climatisation ou d&rsquo;humidification.</p>
<p>Solution :<br />
Avant toute autre opération, coupez la ventilation sur OFF si jamais le taux d&rsquo;humidité dans la cave est trop élevé. Le retour à une humidité normale peut prendre quelques jours selon les cas.<br />
Si malgré cela l’humidité reste trop élevée, vérifiez avec un hygromètre que la valeur de la sonde est correcte. Si ce n&rsquo;est pas le cas, calibrer la sonde (Voir manuel de mise en service).<br />
Vérifiez que les condensats de l&rsquo;appareil sont bien évacués à l&rsquo;extérieur et ne saturent pas l&rsquo;atmosphère de la cave.<br />
Vérifiez qu&rsquo;aucune ventilation extérieure ne perturbe le fonctionnement de la climatisation et n&rsquo;ajoute un excès d&rsquo;humidité.<br />
Installez un Winesupervisor 3 qui permettra de vérifier la stabilité de la température et de l&rsquo;humidité et de réaliser des analyses techniques sur le fonctionnement de la cave.</p>
<p>Si malgré cela le taux d&rsquo;humidité dans la cave reste trop élevé, contactez votre installateur ou votre distributeur qui contactera le service client Friax.</p>
<span class="et_bloom_bottom_trigger"></span><p>This article <a href="https://friax.fr/alarme-ahrh-humidite-trop-forte/">Alarme AHRH humidité trop forte</a> first appeared on <a href="https://friax.fr">FRIAX Industrie</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Les alarmes et défauts</title>
		<link>https://friax.fr/les-alarmes-et-defauts/</link>
		
		<dc:creator><![CDATA[Friax Industrie]]></dc:creator>
		<pubDate>Wed, 22 Sep 2021 13:44:41 +0000</pubDate>
				<category><![CDATA[Alarmes]]></category>
		<category><![CDATA[La Régulation Friax (FR)]]></category>
		<category><![CDATA[Les Monoblocs (FR)]]></category>
		<category><![CDATA[Les Splits EVA (FR)]]></category>
		<category><![CDATA[Les Splits EVG/EVI (FR)]]></category>
		<category><![CDATA[Les Splits EVPL (FR)]]></category>
		<category><![CDATA[Les Splits EVX (FR)]]></category>
		<guid isPermaLink="false">https://friax.fr/?p=66921</guid>

					<description><![CDATA[<p>Une LED rouge est allumée en façade ? Votre télécommande affiche un message ? &#160; Message d&#8217;alarme Source de l&#8217;erreur Désignation Type d&#8217;erreur AS1c Sonde T° cave Coupure sonde température cave Genesis 2 A SL Température cave seuil bas 1 A SH Température cave seuil élevé 1 A SO Défaut température cave 2 AS2c Sonde [&#8230;]</p>
<p>This article <a href="https://friax.fr/les-alarmes-et-defauts/">Les alarmes et défauts</a> first appeared on <a href="https://friax.fr">FRIAX Industrie</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Une LED rouge est allumée en façade ?</h2>
<h2>Votre télécommande affiche un message ?</h2>
<p>&nbsp;</p>
<table style="border-collapse: collapse; width: 100%; height: 272px;" border="1">
<tbody>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><strong>Message d&rsquo;alarme</strong></td>
<td style="width: 25%; height: 17px; text-align: center;"><strong>Source de l&rsquo;erreur</strong></td>
<td style="width: 25%; height: 17px; text-align: center;"><strong>Désignation</strong></td>
<td style="width: 25%; height: 17px; text-align: center;"><strong>Type d&rsquo;erreur</strong></td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><a href="https://friax.fr/alarme-as1c/" target="_blank" rel="noopener">AS1c</a></td>
<td style="width: 25%; height: 68px; text-align: center;" rowspan="4">Sonde T° cave</td>
<td style="width: 25%; height: 17px;">Coupure sonde température cave Genesis</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><a href="https://friax.fr/alarme-asl/" target="_blank" rel="noopener">A SL</a></td>
<td style="width: 25%; height: 17px;">Température cave seuil bas</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">A SH</td>
<td style="width: 25%; height: 17px;">Température cave seuil élevé</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">A SO</td>
<td style="width: 25%; height: 17px;">Défaut température cave</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><a href="https://friax.fr/alarme-as2c/" target="_blank" rel="noopener">AS2c</a></td>
<td style="width: 25%; height: 68px; text-align: center;" rowspan="4">Sonde T° + HR cave<br />
(avec modèles Vintage)</td>
<td style="width: 25%; height: 17px;">Coupure sonde température cave Vintage</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><a href="https://friax.fr/alarme-asl/" target="_blank" rel="noopener">A SL</a></td>
<td style="width: 25%; height: 17px;">Température cave seuil bas</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">A SH</td>
<td style="width: 25%; height: 17px;">Température cave seuil élevé</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">AHRH</td>
<td style="width: 25%; height: 17px;">Humidité cave seuil élevé</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">A SO</td>
<td style="width: 25%; height: 68px; text-align: center;" rowspan="4">Sonde T° condenseur</td>
<td style="width: 25%; height: 17px;">Défaut température cave</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;"><a href="https://friax.fr/alarme-as3c/" target="_blank" rel="noopener">AS3c</a></td>
<td style="width: 25%; height: 17px;">Coupure sonde température condenseur</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">AS3H</td>
<td style="width: 25%; height: 17px;">Température condenseur seuil élevé</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">AS3O</td>
<td style="width: 25%; height: 17px;">Défaut température condenseur</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">AVEc</td>
<td style="width: 25%; height: 17px; text-align: center;">Ventilateur évaporateur</td>
<td style="width: 25%; height: 17px;">Défaut ventilateur condenseur</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">AVCc</td>
<td style="width: 25%; height: 17px; text-align: center;">Ventilateur condenseur</td>
<td style="width: 25%; height: 17px;">Défaut ventilateur condenseur</td>
<td style="width: 25%; height: 17px; text-align: center;">2</td>
</tr>
<tr style="height: 17px;">
<td style="width: 25%; height: 17px; text-align: center;">A rF</td>
<td style="width: 25%; height: 17px; text-align: center;">Perte rF (Radio Fréquence)</td>
<td style="width: 25%; height: 17px;">Perte de communication radio fréquence</td>
<td style="width: 25%; height: 17px; text-align: center;">1</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h3>Deux cas de figure :</h3>
<p><strong>Alarme Type 1</strong> &gt;&gt; Notification &#8211; Le climatiseur continu de fonctionner.<br />
<em>LED verte Fixe + LED rouge clignotante en façade coté cave</em><br />
<em>Message d’alarme sur la télécommande et bouton OK qui clignote</em></p>
<p><strong>Alarme Type 2</strong> &gt;&gt; Le climatiseur ne fonctionne plus &#8211; Contactez votre revendeur !<br />
<em>LED rouge en façade coté cave</em><br />
<em>Message d’alarme sur la télécommande et bouton OK qui clignote quand une touche est enfoncée</em></p>
<p>Une fois le problème résolu, vous pouvez redémarrer l’appareil en appuyant sur le bouton de synchronisation située en façade ou sur <strong>OK</strong></p>
<span class="et_bloom_bottom_trigger"></span><p>This article <a href="https://friax.fr/les-alarmes-et-defauts/">Les alarmes et défauts</a> first appeared on <a href="https://friax.fr">FRIAX Industrie</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>